Table 3.1 - Port Locations andDIP Switch Settings
Host
SW1 Bits
I/O
Address
6
5
4
3
2
1
Remarks
0x0200
OFF
OFF
OFF
OFF
OFF
OFF
0x0208
OFF
OFF
OFF
OFF
OFF
ON
0x0210
OFF
OFF
OFF
OFF
ON
OFF
0x0218
OFF
OFF
OFF
OFF
ON
ON
0x0220
OFF
OFF
OFF
ON
OFF
OFF
0x0228
OFF
OFF
OFF
ON
OFF
ON
0x0230
OFF
OFF
OFF
ON
ON
OFF
0x0238
OFF
OFF
OFF
ON
ON
ON
0x0240
OFF
OFF
ON
OFF
OFF
OFF
0x0248
OFF
OFF
ON
OFF
OFF
ON
0x0250
OFF
OFF
ON
OFF
ON
OFF
Default (See Note)
0x0258
OFF
OFF
ON
OFF
ON
ON
(See Note)
0x0260
OFF
OFF
ON
ON
OFF
OFF
(See Note)
0x0268
OFF
OFF
ON
ON
OFF
ON
(See Note)
0x0270
OFF
OFF
ON
ON
ON
OFF
0x0278
OFF
OFF
ON
ON
ON
ON
0x0280
OFF
ON
OFF
OFF
OFF
OFF
0x0288
OFF
ON
OFF
OFF
OFF
ON
0x0290
OFF
ON
OFF
OFF
ON
OFF
0x0298
OFF
ON
OFF
OFF
ON
ON
0x02A0
OFF
ON
OFF
ON
OFF
OFF
0x02A8
OFF
ON
OFF
ON
OFF
ON
0x02B0
OFF
ON
OFF
ON
ON
OFF
0x02B8
OFF
ON
OFF
ON
ON
ON
0x02C0
OFF
ON
ON
OFF
OFF
OFF
0x02C8
OFF
ON
ON
OFF
OFF
ON
0x02E0
OFF
ON
ON
ON
OFF
OFF
0x02E8
OFF
ON
ON
ON
OFF
ON
0x02F0
OFF
ON
ON
ON
ON
OFF
0x02F8
OFF
ON
ON
ON
ON
ON
PC Serial Port 2
0x0600
ON
OFF
OFF
OFF
OFF
OFF
0x0608
ON
OFF
OFF
OFF
OFF
ON
0x0610
ON
OFF
OFF
OFF
ON
OFF
0x0618
ON
OFF
OFF
OFF
ON
ON
0x0660
ON
OFF
OFF
ON
OFF
OFF
0x0668
ON
OFF
OFF
ON
OFF
ON
0x0630
ON
OFF
OFF
ON
ON
OFF
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (1 page)
- 100 Contactors with DC Coil (2 pages)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)