Rockwell Automation 1734-APB Point I/O Profibus Adapter Module User Manual
Point i/o profibus adapter module
Table of contents
Document Outline
- 1734-UM005B-EN-P, POINT I/O PROFIBUS Adapter Module User Manual
- Important User Information
- Preface
- Table of Contents
- Chapter 1
- Chapter 2
- Installing the PROFIBUS Adapter
- General
- Installing the PROFIBUS Adapter
- 1. Position the adapter vertically above the DIN rail.
- 2. Press down firmly to install the adapter on the DIN rail. (The locking mechanism will lock the...
- 3. Insert the PROFIBUS network plug and tighten the holding screws.
- 4. Set the node address using the 2-position thumbwheel switch. Valid settings range from 01 to 9...
- 5. Slide the safety end cap (9) up to remove. This exposes the backplane and power interconnections.
- Installing a Replacement PROFIBUS Adapter to an Existing System
- A. Pull up on the removable terminal base (RTB) removal handle (7) to remove the terminal block.
- B. Loosen the screws holding the PROFIBUS network plug and pull up to remove.
- C. Remove the adjacent module from its base.
- D. Use a small bladed screwdriver to rotate the DIN rail locking screw (5) to a vertical position...
- E. Pull straight out to remove.
- 2. Set the desired node address on the replacement adapter.
- 3. Slide the safety end cap up and remove it from the replacement adapter. This exposes the backp...
- 4. Position the replacement adapter vertically above the DIN rail. (Make certain the DIN rail loc...
- 5. Press firmly to seat the adapter (1) on the DIN rail. The adapter locking mechanism will snap ...
- 6. Insert the PROFIBUS network plug and tighten the holding screws.
- 7. Insert the end opposite the handle into the base unit. This end has a curved section that enga...
- 8. Rotate the terminal block into the wiring base until it locks itself in place.
- 9. Replace the adjacent module in its base.
- Wiring the PROFIBUS Adapter
- Chapter Summary and What’s Next
- Chapter 3
- Configuring the POINT I/O System
- In This Chapter
- Configuration Overview
- Installing the GSD File
- 1. Open the file.
- 2. Select “Copy GSD”
- Adding the Master to the Network
- Adding the Adapter to the Network
- Adding I/O Modules to the Adapter
- Configuring I/O Modules
- Download to Master System
- Chapter Summary and What’s Next
- Chapter 4
- Communication and I/O Table Mapping
- Image Table Mapping
- How Data Communication Takes Place
- Grouping Modules for Memory Management
- Chapter Summary and What’s Next
- Chapter 5
- Grouped Mode
- In This Chapter
- General
- How to Configure the Adapter for Grouped Mode
- 1. Module without configuration data (e.g. 1734-OB2E/no config)
- 2. Module with configuration data (e.g. 1734-OB2E/with config)
- 3. Empty slot module (e.g. 1734-OB2E/empty slot)
- 4. Grouped module (e.g. 1734-OB2E/grouped)
- 5. Grouped empty slot module (e.g. 1734-OB2E/grouped empty slot)
- 1. A group of modules with configuration data
- 2. A group of modules without configuration data (default configuration will be used for all modu...
- 3. A group of empty slot modules
- Configuration Example
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 1734-OB2E
- 1734-OB2E/grouped
- 1734-OB2E/grouped
- 1734-OB2E/grouped
- 1734-OB4E/empty slot
- 1734-OB4E/grouped empty slot
- 1734-IB2E
- 1734-IB2E/grouped
- 1734-IV2E/grouped
- 1734-OE2C
- 1734-IE2C
- 1734-IB4/no configuration
- 1734-IB4/grouped
- 1734-IB4
- 0.0 to 0.1
- 0.2 to 0.3
- 0.4 to 0.5
- 1 to 4
- 5.0 to 5.3
- 5.4 to 5.7
- 6.0 to 6.3
- 0.0 to 0.1
- 0.2 to 0.3
- 0.4 to 0.5
- 0.6 to 0.7
- 1.0 to 1.3
- 1.4 to 1.7
- 2 to 5
- Same configuration data as first module in group (slot 1).
- Same configuration data as first module in group (slot 7).
- Default configuration data
- Chapter Summary and What’s Next
- Chapter 6
- Appendix A
- Appendix B
- Default Data Maps
- 1734-IB2 Sink Input Module
- 1734-IB4 Sink Input Module
- 1734-IV2 Source Input Module
- 1734-IV4 Source Input Module
- 1734-OB2E Electronically Protected Output Module
- 1734-OB4E Electronically Protected Output Module
- 1734-OW2 Relay Sink/Source Output Module
- 1734-IE2C Analog Current Input Module
- 1734-OE2C Analog Current Output Module
- 1734-IE2V Analog Voltage Input Module
- 1734-OE2V Analog Voltage Output Module
- 1734-IA2 120V ac Input Module
- 1734-IM2 220V ac Input Module
- 1734-OA2 120/220V ac Output Module
- Numerics
- A
- B
- C
- D
- G
- H
- I
- M
- N
- P
- R
- S
- T
- W
- Index
- Publication Problem Report