Cable connector handling and maintenance, Supported drives – Rockwell Automation 1784-PM16SE 16 Axis PCI SERCOS interface Card Installation Instructions User Manual
Page 20

20 16 Axis PCI SERCOS interface Card
Publication 1784-IN041A-EN-P – June 2003
Cable Connector Handling and Maintenance
When cables are not in use, keep the ends covered with the dust covers that
came with the cables. This helps to keep dust and small particles from
blocking the optic path. Good system performance is dependent on clean
port optics and cable ferrules to avoid obstructing the optical path. Clean
compressed air is often sufficient to remove particles of dirt. You can also
use methanol on a cotton swab. Recommended cleaners include:
Supported Drives
The following Allen-Bradley drives are supported by the SERCOS interface
motion card.
Alcohols
Aliphatics
Other
methyl
hexane
soap solution
isopropyl
heptane
naphtha
isobutyl
ATTENTION
!
The small junction size inherent in the design of these
components increases the components’ susceptibility to
damage from electrostatic discharge (ESD). It is advised
that normal static precautions be taken in handling and
assembly of these components to prevent damage and/
or degradation which can be induced by ESD.