Rockwell Automation 1784-KT2/C INST.DATA COMM.INTERFACE MOD. User Manual
Page 28

Communication Interface Module
Cat. No. 1784-KT2/C
Installation Data
28
Figure 4
The Output File For a Card Diagnostics Test
CARD DIAGNOSTICS
PASS:ą1
OF
2
Wed Aug 22 11:48:13 1990
Start/Stop 1784-KT2 Proce . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Dual Port (KT2 side) . . . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Interrupts (PS2 to KT2) . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Memory . . . . . . . . . . . . . . . . .
ąError Code: 128 RAM1 Failure.
NUM FAILS:
1
PASS/FAIL:
FAIL
Timer Operation . . . . . . . . . . .
ąError Code: 16 CTC Counter
ąMode Failure.
NUM FAILS:
1
PASS/FAIL:
FAIL
Serial Port Operation . . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
CARD DIAGNOSTICS
PASS:ą2
OF
2
Wed Aug 22 11:48:16 1990
Start/Stop 1784-KT2 Proce . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Dual Port (KT2 side) . . . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Interrupts (PS2 to KT2) . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Memory . . . . . . . . . . . . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Timer Operation . . . . . . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
Serial Port Operation . . . . . . .
ąError: No error found.
NUM FAILS:
0
PASS/FAIL:
PASS
CARD DIAGNOSTICS
FINAL RESULTS
Wed Aug 22 11:48:17 1990
Start/Stop 1784-KT2 Proce. . . .
NUM FAILS:
0
PASS/FAIL:
PASS
Dual Port (KT2 side) . . . . . . . .
NUM FAILS:
0
PASS/FAIL:
PASS
Interrupts (PS2 to KT2) . . . . . .
NUM FAILS:
0
PASS/FAIL:
PASS
Memory . . . . . . . . . . . . . . . . .
NUM FAILS:
1
PASS/FAIL:
FAIL
Timer Operation . . . . . . . . . . .
NUM FAILS:
1
PASS/FAIL:
FAIL
Serial Port Operation . . . . . . .
NUM FAILS:
0
PASS/FAIL:
PASS
In the above example, the Card Diagnostics test was run twice. The timer
operation and the memory diagnostics show errors in the first pass of tests
and none in the second pass. The final results section indicates the failure
of both diagnostics from the first run of tests.