Communication Interface Module
Cat. No. 1784-KT2/C
Installation Data
22
Table 2
Host Diagnostics Screen Definitions
This term:
Indicates:
Configuration
the 1784-KT2's configuration parameters.
Memory Address
the 1784-KT2's configured memory address.
Interrupt Level
the 1784-KT2's configured interrupt level.
Mode Selection
the 1784-KT2's configured auxiliary communication port.
Adapter ID
the 1784-KT2's adapter identification number (60C6).
Dual Port
(PS2 side)
test results of the PS/2's ability to read/write to and from the dual port
memory. If any errors occur, the failure counter increments and
continues with the next text.
Power On/Reset
test results of the PS/2's ability to reset the 1784-KT2. After reset, the
1784-KT2's status and execution capabilities are verified. If any errors
occur, the failure counter increments and continues with the next test.
Interrupts
(KT2 to PS2)
test results of the interrupt capabilities from the 1784-KT2 to the PS/2.
If the PS/2 cannot receive an interrupt from the 1784-KT2, the failure
counter increments and continues with the next test.
The Host Diagnostics test runs according to the number of times
specified in step two. Your screen shows you when the tests are
complete (Status column), how many errors were discovered
(Failures column), and final test results (Result column).
3.
When you are finished, press any key to return to the main menu.
The Card Diagnostics Test
The Card Diagnostics option allows you to test the 1784–KT2’s various
components and operations. To perform this test, follow these steps:
1.
Place your cursor on the Card option and press [ENTER].
2.
You are asked if you want to run a single test (Single Pass) or a
specified number of tests (Repeat). Place your cursor on Single Pass
or on Repeat and press [ENTER].
If you choose Repeat, you are asked how many passes you want to
make. Specify this number and press [ENTER].