Publication 1769-IN067B-EN-P - September 2005

Configuration Data File

The manipulation of the bits from this file is normally done with programming
software (e.g. RSLogix 500, RSNetworx for DeviceNet, etc.) during initial
configuration of the system. In that case, graphical screens are provided by the
programmer to simplify configuration. However, some systems, like the 1769-ADN
DeviceNet Adapter, also allow the bits to be altered as part of the control program,
using communication rungs. In that case, it is necessary to understand the bit
arrangement. Refer to the Compact™ Analog I/O User Manual, publication number

1769-UM002 for additional details.

Wo

rd

Bit Position

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

0

Real Time Sample Value

1

ERTS

Reserved

2

EC

Reserved

EA

AL

EI

Reserved

Input Filter Sel Chl0

3

Reserved

Inpt Dta Fm Chl0

Reserved

Inpt Tp/RngeSel Chl0

4

S

Process Alarm High Data Value Channel 0

5

S

Process Alarm Low Data Value Channel 0

6

S

Alarm Dead Band Value Channel 0

7

Pad

8

EC

Reserved

EA

AL

EI

Reserved

Inpt Filter Sel Chl1

9

Reserved

Inpt Dta Fm Chl1

Reserved

Inpt Tp/RngeSel Chl1

10

S

Process Alarm High Data Value Channel 1

11

S

Process Alarm Low Data Value Channel 1

12

S

Alarm Dead Band Value Channel 1

13

Pad

14

EC

Reserved

EA

AL

EI

Reserved

Input Filter Sel Chl2

15

Reserved

Inpt Dta Fm Chl2

Reserved

Inpt Tp/RngeSel Chl2

16

S

Process Alarm High Data Value Channel 2

17

S

Process Alarm Low Data Value Channel 2

18

S

Alarm Dead Band Value Channel 2

19

Pad

20

EC

Reserved

EA

AL

EI

Reserved

Input Filter Sel Chl3

21

Reserved

Inpt Dta Fm Chl3

Reserved

Inpt Tp/RngeSel Chl3

22

S

Process Alarm High Data Value Channel 3

23

S

Process Alarm Low Data Value Channel 3

24

S

Alarm Dead Band Value Channel 3

25

Pad

26

EC

Reserved

EA

AL

EI

Reserved

Input Filter Sel Chl4