Application example 1, Example 1: system layout – Rockwell Automation 440R-S845AER-NNL MSR57P GuardMaster Speed Monitoring Safety Relay User Manual
Page 8

8 GuardMaster MSR57P Speed Monitoring Safety Relay
Publication 440R-IN016B-EN-P - November 2008
Application Example 1
Example 1: System Layout
This example is configured for Safe
Stop 1. The control cabinet
contains an MSR57P relay, a
PowerFlex 70 AC Drive with
Safe-Off function, as well as a
PanelView terminal. The MSR57P
relay monitors speed via a TTL
encoder connected to the
PowerFlex 70 drive.
The control panel lets the operator
select Run or Maintenance speeds.
The door has an interlock switch
with guardlocking to limit access
to the machine when the machine
is operating at normal Run speed.
A towerlight indicates machine
status.
E-Stop
Reset
Run
Maintenance
Mode
Stopped
Safe Speed
Running
S32
S52 S62
S42
13
24 A1
14
S11
S12 S22
S21
34
51 52
44
S72
X32 X42
S82
Y1
S34 Y37
Y2
Y31
Y33 Y30
Y32
68
Y35 A2
78
Encoder 1
PWR/Fault
Stop
Config
Lock
Inputs
Status
Limited Speed
Standstill
Safe Speed
Motion Power Door
Encoder 2
DPI
P
M
PowerFlex 70 Drive With Safe-Off
Safe
Stop
SLS
Request
Configuration Tools
MSR57P Relay
Primary Encoder
(Example, Catalog Number:
845T-HZ42EEN)
Guardlocking
Switch
TLS3-GD2
Motor
Power
Cable
Encoder
Input 1
Encoder
Feedback
Cable
Start/Stop Command
and Motion Power
Outputs
20-HIM-A3
Encoder Cable
1585J-M8RB-2M5
1203-USB or
1203-SSS(B)
20-HIM-H10
PC
-OR-