Rockwell Automation 440R-S845AER-NNL MSR57P GuardMaster Speed Monitoring Safety Relay User Manual
Page 7

GuardMaster MSR57P Speed Monitoring Safety Relay 7
Publication 440R-IN016B-EN-P - November 2008
Environmental Specifications
Attribute
Value
Temperature, operating -5…55 °C (23…131 °F)
Relative humidity
90% RH noncondensing
Vibration
10…55 Hz, 0.35 mm displacement
Shock, operating
10 g, 16 ms, 100 shocks
ESD immunity
4 kV contact discharges; 8 kV air discharges
Radiated RF immunity
10 V/m from 80…1000 MHz; 3 V/m from 1.4…2.0 GHz;
1V/m from 2.0…2.7GHz
EFT/B immunity
Power, dc: ±2 kV
I/O signal lines: ±1 kV
Surge transient immunity Power, dc: ±0.5 kV line-line and ±0.5 kV line-earth
I/O signal lines: ±1 kV line-earth
Conducted RF immunity 10V rms from 150 kHz…80 MHz
Certifications
Certification
(1)
Value
c-UL-us
UL Listed, certified for US and Canada.
CE
European Union 2004/108/EC EMC Directive, compliant with:
•
EN 61000-6-4; Industrial Emissions.
•
EN 61131-2 Programmable Controllers (Clause 8, Zone A & B).
•
EN 61326-3-1; Meas./Control/Lab., Industrial Requirements.
•
EN 61000-6-2; Industrial Immunity.
C-Tick
Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions.
TÜV
TÜV Certified for Functional Safety: SIL CL1 to CL3, according to IEC 61508/EN62061;
Category 1 to 4 and Performance Level e, according to EN ISO 13849-1, when used as
described in the GuardMaster MSR57P Speed Monitoring Safety Relay User Manual,
publication 440R-UM004.
(1)
When product is marked. See the Product Certification link at
other certifications details.