Main control panel, Remove components – Rockwell Automation 20B PowerFlex 700 Drive Components Replacement - Frame 8 User Manual
Page 24

24
Rockwell Automation Publication 20B-IN024C-EN-P - June 2012
Chapter 2
Basic Component Removal Procedures
Main Control Panel
Chapter 1 - Component Diagrams and Torque Specifications
to locate the
component detailed in these instructions.
Remove Components
1. Read and follow the
2. Remove the ribbon cable going from the main control board (J2) to the
power interface board ( J1).
3. Disconnect the incoming ground wire to TB11.
4. Remove the two screws on the main control panel below TB11.
5. Remove the two mounting nuts at the top of the main control panel.
6. Disconnect the wire harnesses from TB11 to the switch mode power
supply board ( J4 connector) and at TB1 and TB2 on the power interface
board.
7. Label and remove all customer wiring from TB11.
8. Remove the main control panel and carefully set aside.
Ribbon
Cable
Mounting Nuts (2) at top
of Main Control Panel
Ground Wire
to TB11
MCP Mounting Screws (2) below TB11
Mounting Nuts (2) at top
of Main Control Panel
Ground Wire
to TB11
MCP Mounting Screws (2) below TB11
Mounting Nuts (2) at top
of Main Control Panel
Ground Wire
to TB11
Main Control Panel Mounting Screws (2) below TB11