End of life - not recommended for new designs, Batpac, Modupac juniorpac rampac – Vicor Autoranging MegaPAC AC-DC Switcher User Manual
Page 9: Dualpac, Flexpac, Modupac/jr.pac/rampac
UG:106
vicorpower.com
Applications Engineering: 800 927.9474
Page 9
ConverterPAC Output and Connector Pin Identification for the A/R MegaPAC
ModuPAC
JuniorPAC
RAMPAC
J2-PIN1
J3-PIN1
+ V0UT
- VOUT
(REMOTE SENSE)
J2
2
1
3
- SENSE
+ SENSE
MATING HDWR:
TRIM PIN ACCESS
3
POWER GOOD
2
1
SIGNAL GROUND
POWER GOOD INVERTED
MATING HDWR:
4
J3 DC OK (POWER GOOD)
Vcc IN
HOUSING- MOLEX P/N: 50-57-9403
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 11-01-0118
HOUSING- MOLEX P/N: 39-01-0043
TERMINALS- MOLEX P/N: 30-00-0031
CRIMP TOOL MOLEX P/N: 57005-5000
MODUPAC/JR.PAC/RAMPAC
R4-(OUTPUT ADJUST)
DualPAC
J2-B-PIN1
OUTPUT ADJUST
J2-A-PIN1
J2 (REMOTE SENSE)
MATING HDWR:
HOUSING- MOLEX P/N: 50-57-9403
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 11-01-0208
3
- SENSE
+ SENSE
1
TRIM PIN ACCESS
2
OUTPUT ADJUST
J1-B-PIN1
J1-A-PIN1
(OUTPUT CONNECTORS)
1 AND 4 +V OUT
3
3 +R/SENSE 6 -R/SENSE
1
2
J1
TERMINALS- MOLEX P/N: 39-00-0039
HOUSING- MOLEX P/N: 39-01-2060
CRIMP TOOL MOLEX P/N: 11-01-0197
MATING HDWR:
6
5
4
2 AND 5 -V OUT
DUALPAC
20-130182-TAB
J1-B (M1)
J1-A (M2)
M2
M1
Output A
48V/2.1A
Output B
12V/8.3A
Example: D12V/8.3A-48V/2.1A
DUALPAC - COMPONENT SIDE VIEW
VOLTAGE LIMIT ADJUST
J2 (BATPAC REMOTE INTERFACE)
CURRENT MONITOR
CURRENT LIMIT ADJUST
- VOUT
VOLTAGE LIMIT ADJUST
1
- VOUT
3
2
4
J2-PIN1
CURRENT LIMIT ADJUST
CRIMP TOOL MOLEX P/N: 57005-5000
TERMINALS- MOLEX P/N: 30-00-0031
HOUSING- MOLEX P/N: 39-01-0043
MATING HDWR:
BATPAC
+ V0UT
BatPAC
M-1 STATUS
M-1 VOLTAGE ADJUSTMENT
M-4 STATUS
M-3 STATUS
M-2 VOLTAGE ADJUSTMENT
M-2 STATUS
M-4 VOLTAGE ADJUSTMENT
M-3 VOLTAGE ADJUSTMENT
CONNECTOR
J1
FlexPAC
MATING HDWR:
HOUSING MOLEX P/N 39-01-2120
TERMINALS MOLEX P/N 39-00-0039
CRIMP TOOL MOLEX P/N 11-01-0197
End of Life - Not Recommended for New Designs