Current Share Boards - Optional Feature (Cont.)

Figure 12. Cable Drawing

(page 2)

P 1

24.0" +/- 1.0"

Power

T 1

-V1

T 2

-V2

Red, 22 AWG

Yellow, 22 AWG

Brown, 22 AWG

White, 22 AWG

Black, 22 AWG

1

2

3

4

5

6

1.74"

(44.2mm)

0.12"

(3.0mm)

1.500"

(38.1mm)

0.12"

(3.0mm)

0.900"

(22.9mm)

1.14"

(29.0mm)

0.13" (3.3mm) Dia Non
Plated thru hole 4
places

Molex CT43045F surface mountable
connector. .390" height above board.

Pin

Description

1

P o w e r

2

T 1

3

- V 1

4

T 2

5

- V 2

6

No Connection

J1 Pinout

Figure 11. Mechanical Drawing

Specifications:
1.
Power: 2-50 Vdc at 5 mA maximum.
2. Accuracy: +/- 1 mV between -Vout connections.
3. Output current when not trimming up: +/- 1 uA (VI-200/J00), +/-5 uA (Maxi).
4. Use 4 non-plated through holes with standoffs for mounting.
5. CSB01 MUST be used for current sharing VI-200/VI-J00 converters.
6. CSB02 MUST be used for current sharing Maxi converters .

Please note:

The CSB is NOT intended for Hotswap Applications

End of Life - Not Recommended for New Designs