Input Characterisitcs
Input Voltage
115-230 Vac, 1 Phase, 90-132 Vac, 180-264 Vac, (47-500 Hz) 260-352 Vdc
Power Factor (passive)
0.65
Inrush Current
30A rms @ 115 Vac
60A rms @ 230 Vac
Ride Through Time
>20 ms at nominal line, full load
Power Fail
>3 ms warning
Conducted EMI (47-63 Hz) EN55022 Level A
Surge Immunity
(Common
Mode and Normal Mode)
EN 61000-4-5 Class 3
(Temporary loss of output power may occur which is self recoverable)
Dielectric Withstand
Primary to Chassis GND = 2,121 Vdc
Primary to Secondary = 4,242 Vdc
Secondary to Chassis GND = 750 Vdc
Ouput Characterisitcs
Line/Load Regulation*
0.2% max. from 10% to 100% load
0.5% max. from 0% to 10% load
Setpoint Accuracy
1% for standard voltages
2% for special, adjustable voltages or 48 Vdc
Ripple and Noise
Std. outputs: 2% or 100 mV p-p, whichever is greater, 75% min. load;
VXI options: 50 mV p-p for output voltages <15 Vdc; 150 mV p-p for
output voltages > 15 V and up to and including 24 V; 1% maximum for output
voltages > 24 V. (VXI requires 15% minimum load)
RAMPAC: 10 mVp-p max.or 0.15% whichever is greater
FlexPAC: Mets VXI requirement over total output range
Output Trim Range
50% -110% of nominal voltage VI-200/VI-J00 modules
90% -110% of nominal voltage VI-200/VI-J00 modules 10-15 V
2 V - 25V FlexPACs
Overcurrent Trip Point
105-125% of full load capability of VI-200/VI-J00 modules
Dependent on voltage set for FlexPAC - contact factory
Overvoltage Protection
ModuPACs: 115- 135%; FlexPACs 125% set voltage
Efficiency
Up to 82% typical
Output Power
1,600 W at at 230 Vac;
1,200 W at at 115 Vac
Environmental Characteristics
Storage Temperature
-40°C to +85°C
Operating Temperature**
-20°C to +45°C full power, -20°C to +65°C half power
Humidity
0-95% non-condensing
Altitude
Derate 2.6% total output power for each 1,000 ft to a maximum operating
altitude of 15,000 ft. Non-operating storage maximum altitude is 40 K
Safety Approvals
cURus – UL 60950-1, CSA 60950-1
cTUVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 73/23/EEC amended by 93/68/EEC
Product Weights
9.0 lbs. (4,08 kg) fully configured
0.7 lbs. (0,32 kg) ConverterPAC
Warranty
2 years limited warranty.
for complete warranty statement.
* See Vicor module specifications. A preload may be necessary for modules trimmed down below
90% of normal output voltage.
** The maximum operating temperature is 45°C. If one is using a VI-200 with output voltage less than
12 V and more than 150 Watts, the operating temperature decreases to 40°C.