Application guide, Specifications – USG Ceiling True Wood User Manual
Page 31
Specifications
aPPliCaTion
GUide
3.03
installation
A. Ceiling Framing:
1. Standard reference: Install grid members in accordance with ASTM C636, CISCA
installation standards, and other applicable references.
2. Manufacturer's reference: Install in accordance with manufacturer's current printed
recommendations.
3. Drawing reference: Install in accordance with approved shop drawings and locate
ceiling in accordance with main tee dimensions relative to elevations.
4. Hanger Wire Installation: Secure hanger wires to upper structural elements and
space hangers so that each hanger wire supports a maximum of 16 sq. ft.
5. Space main tee members a maximum span of 48" on center. Space cross tees to
achieve a 2' x 2' grid for 2' x 2' panels or 4' x 4' grid for 4' x 4' panels.
B. Ceiling Panels
1. Preparation: Remove dirt and debris from surrounding area. Comply with
manufacturer's written instructions.
2. Install ceiling panels in accordance with approved shop drawings
3.04
Cleaning
A. Suspension system: Remove infill material and perform any necessary cleaning
maintenance with non-solvent based commercial cleaner.
B. Touch up all minor scratches and spots, as acceptable, or replace damaged sections
when touch up is not permitted.
C. Painting: Repainting of suspension members shall be with a high-quality solvent base
paint and applied as recommended by paint manufacturer.
D. Removal of debris: Remove all debris resulting from work of this section.
E. Clean exposed surfaces of ceiling systems. Comply with manufacturer's written
instructions for cleaning and touchup of minor finish damage. Remove and replace
ceiling system components that cannot be successfully cleaned and repaired to
permanently eliminate evidence of damage, including dented and deformed members.
Manufactured by
United States Gypsum Company
550 West Adams Street
Chicago, IL 60661
The trademarks USG, CENTRICITEE, COMPASSO, DX, DXF,
DXFF, DXL, DXLT, FINELINE, SHADOWLINE, TRUE WOOD,
IT’S YOUR WORLD. BUILD IT., THE USG LOGO, and related
marks are trademarks of USG Corporation or its affiliates.
IC561/rev. 7-14
© 2014 USG Corporation and/or
its affiliates. All rights reserved.
Printed in U.S.A.
Safety First! Follow good safety/industrial hygiene
practices during installation. Wear appropriate
personal protective equipment. Read MSDS and
literature before specification and installation.