General surface treatment recommendations for l, Floor underlayment to receive floor coverings – USG Levelrock Floor Underlayment Finished Floor User Manual
Page 14
Building Type
Floor covering
Adhesive
L
eveLrock
Floor
Underlayment
recommended
Surface Treatment
For L
eveLrock
Floor
Underlayment
comments
reSIDeNTIAL /
WooD FrAMe /
MULTI-FAMILY
CARPET
WBA
2500, RH
APS/FTP
FELT-BACKED VINYL
WBA
2500, RH
APS/FTP
VINYL COMPOSITION TILE
WBA
2500, RH
APS/FTP
CERAMIC TILE
THINSET
2500, RH
APS/FTP
WOOD LAMINATE, WOOD
PLANK
URETHANE
2500, RH
NONE
Use of an adhesive manufacturer’s
proprietary primer may be required .
coMMercIAL / 2- &
3-STorY WooD
FrAMe / HoTeL,
MoTeL, ASSISTeD
LIvING
CARPET
WBA
2500, 3500, Commerical RH
APS/FTP
Use FTP where urine-resistance is
required .
FELT-BACKED VINYL
WBA
2500, 3500, Commerical RH
APS/FTP
Use FTP where urine-resistance is
required .
VINYL COMPOSITION TILE
WBA
2500, 3500, Commerical RH
APS/FTP
Use FTP where urine-resistance is
required .
LINOLEUM
WBA
2500, Commerical RH
APS/FTP
Use FTP where urine-resistance is
required .
CERAMIC TILE
THINSET
2500, 3500, Commerical RH
APS/FTP
Use FTP where urine-resistance is
required .
WOOD LAMINATE, WOOD
PLANK
URETHANE
2500, 3500, Commerical RH
NONE
Use of an adhesive manufacturer’s
proprietary primer may be required .
reSIDeNTIAL /
corrUGATeD STeeL
Deck LIGHT-GAUGe
STeeL FrAMING /
coNDo
CARPET
WBA
CSD
®
e
arLy
e
xpoSure
™
NONE
pH adjustment may be required .
Check with adhesive manufacturer .
FELT-BACKED VINYL
WBA
CSD e
arLy
e
xpoSure
NONE
pH adjustment may be required .
Check with adhesive manufacturer .
VINYL COMPOSITION TILE
WBA
CSD e
arLy
e
xpoSure
NONE
pH adjustment may be required .
Check with adhesive manufacturer .
CERAMIC TILE
THINSET
CSD e
arLy
e
xpoSure
NONE
WOOD LAMINATE, WOOD
PLANK
URETHANE
CSD e
arLy
e
xpoSure
NONE
Use of an adhesive manufacturer’s
proprietary primer may be required .
LeGeND
APS: L
eveLrock
All Purpose Sealer at a 4:1 ratio
FTP: SIKAFLOOR Fast Track Primer at a 4:1 ratio
PSA: Pressure Sensitive Adhesive
WBA: Water Based Adhesive
(water to sealer concentrate) applied at
(water to standard SIKA blend) applied at
300 sq . ft ./gal .
400 sq . ft ./gal .
Note: In all cases , both floor-covering manufacturer and USG recommends that a field bond test be conducted prior to full flooring installation . Allow a minimum of 72 hours before conducting the
pull test . Homogenous vinyl may require an additional 1-2 days . Cool temperatures and high humidity will require additional days .
General Surface Treatment recommendations For L
eveLrock
Floor Underlayment To receive Floor coverings
14