Feature select options – Unisteer Ididit Keyless Ignition User Manual
Page 21
20
Once all features have been set to their desired positions, to exit Feature
Select Mode, depress and HOLD the Brake down for a full 5 seconds until
the Start Button LED begins a LONG fast flashing sequence indicating the
system has exited Feature Select Mode.
Lastly, Push your Start Button 2 times to cycle out of ACC mode and return
to Armed mode and your new features are now operable.
FEAtURE SELECt OPtIONS:
FEAtURE SELECt ( F/S #1)
N/A
FEAtURE SELECt ( F/S #2)
N/A
FEAtURE SELECt ( F/S #3)
N/A
FEAtURE SELECt ( F/S #4)
The
Start Button LED
(Default setting = OFF)
This feature selection allows you to select if you would like the Start Buttons
LED to FLASH when the system is armed or remain OFF. The systems
default setting is set to OFF when Armed. To make the LED FLASH wHEN
THE SYSTEM IS ARMED use the feature Select directions to change F/S
#4 to the second position.
FEAtURE SELECt ( F/S #5)
AUX Output
(Default setting = Momentary)
This feature Select controls the output signal of the AUX Output. A “Long”
push of the Lock button of your Key FOB activates this channel. It Pulses
or Latches a 500ma Negative.
F/S #5 toggles the output setting between Pulse and Latched.