I N S T A L L A T I O N & O P E R A T I O N M A N U A L

FFDE, FFDER, FFDERA Models

Fan Filter Unit IOM

Installation & Operation

Motor/Electrical Removal

Motor Assembly

WARNING

DISCONNECT THE UNIT FROM THE ELECTRICAL

POWER SOURCE BEFORE ATTEMPTING

ANY SERVICE

Service: FFDERA Motor Removal and Installation

WARNING

ELECTRICAL SERVICE SHOULD ONLY BE PERFORMED

BY A LICENSED OR QUALIFIED ELECTRICIAN

Note: Minimum 2 person project.

Tools Required: 3/16 Ball Driver, Phillips screw bit, Head Driver, Battery Operated Drill, (2) 8” adjustable wrenches, 10 mm
hex head wrench, #2 standard screwdriver, and slip joint pliers.

Step 1.

To gain access to the motor, remove the gel seal filter.

Step 2.

Prior to removing motor/blower assembly, remove blower wheel to expose motor connectors on motor. Using an

adjustable wrench loosen the two set screws that attach the blower wheel to the motor shaft. Disconnect the two brown wires from
the capacitor, using a pair of pliers. Disconnect 5-pin and 16-pin wire harnesses from the electrical box housing and remove the tubing
for test port, if installed.

Step 3.

While supporting the motor blower assembly from below, remove the six screws on the underside of the venturi ring

and lower the assembly. (See figure). Note the baffle does not have to be removed to remove the motor/blower assembly.

Step 4

. Before removal of the motor mount bracket, measure the precise location of the bracket on the motor. Remove the

bracket.

Step 5.

Replace with the new motor and reassemble by reversing the above steps. Set the location of the motor mount

bracket as measured (see above Step 6). Set the spacing at 0.25” (6.35 mm) clearance between the blower and the upper
motor plate/prefilter frame creating a 0. 1” (2.80 mm) overlap between the wheel and the venturi ring. When reinstalling the
assembly, align the plate to insure that the leads will reach the electrical box.

18

Plenum

Electrical connectors
located in inner
prefilter wall

Motor/Blower

Assy

Gel Seal Filter

Screen

Blower
Wheel

Wellnut

Venturi
Ring

Motor

Machine Screw
and washer

Grommet