beautypg.com

Maintenance, Fan maintenance - with gtmf remote control – Regency Liberty L390EB Medium Gas Insert User Manual

Page 50

background image

50

L390E-2 / HZI390E-2 Direct Vent Gas Insert

Maintenance

Fan Maintenance - witH gtMF reMOte cOntrOl

FOr l390eB Or HZi390eB

3. Remove fan and fan access panel from unit

4. Remove fan from back access panel by removing 3 screws from the

outside of fan access panel.

5. To install - reverse steps.

2. Disconnect the fan wire harness through the rear panel. Disconnect 2 x

1/4" spade connectors to the fan terminals. Disconnect the ground lug to
the fan using the screw provided.

Fan

Fan Mounting Bracket

Strain Relief

Fan Wire Harness

Ground Wire

Fan Terminals

Power Cord

Fan Controller

Wire Retainer

waRning

Electrical Grounding Instructions

This appliance is equipped with a three-prong

(grounding) plug for your protection against shock

hazard and should be plugged directly into a properly

grounded three-prong receptacle. Do not cut or remove the

grounding prong from this plug.

Diagram 3

Diagram 2

before you begin:
shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
always let the appliance cool to room temperature before servicing.

note: To access the side and rear access panels both the gas and venting

will need to be disconnected(see vent/flue installation in this manual)
for proper removal.

There is no access to the blower from the front of this appliance.

1. Remove 7 screws and loosen 4 screws along the bottom to remove fan

access panel -see Diagram 1a

Remove 4 screws to remove side access panel - see Diagram 1b

Diagram 1b

Diagram 1a

= Remove
= Loosen

This manual is related to the following products: