L390E-2 / HZI390E-2 Direct Vent Gas Insert

25

installation

Fan wiring diagraM

FOr use witH tHe OptiOnal 396-917 Fan FOr l390e/HZi390e)

Caution: ensure that the wires do not touch any

hot surfaces and are away from sharp edges.

Ground

Green

Neutral

Live

Red

Black

Black

Black

Minimum Convection

Air Temp. Switch

Ground

ON

OFF

Rotary Speed

Control

120V AC

Fan

Lockwasher

Ground wire

from power cord

Ground wire

from fan

Star washer

nut

nut

Star washer

Grounding

Lug Detail

cautiOn: label all wires prior to disconnection

when servicing controls. Wiring errors can

cause improper and dangerous operation.