Installation, Materials required, Installation checklist – Regency Liberty L390EB Medium Gas Insert User Manual

Page 11: Minimum fireplace dimensions

background image

L390E-2 / HZI390E-2 Direct Vent Gas Insert

11

installation

A

B

D

E

C

Materials required

No electrical power supply is required for the gas
control to operate. A 120 Volt AC power cord is
hooked up to the fan(if installed). Plug the 3 wire
cord into a suitable receptacle.

Do not cut the

ground terminal off under any circumstances.
When connected with 120 volts, the appliance must
be electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada)
or in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70-1987.

installatiOn

CheCklist

Before installing vent system ensure that the damper
plate is open and secure to prevent the damper plate
from falling down and crushing the liner.

The Regency Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer to

sections "Minimum Fireplace Dimensions and
Clearances to Combustibles)

2) Make the gas connection. (Refer to section "Gas

Connection")

3) Install the two 3" flue liners (intake and exhaust)

to the sliding connector plate. (Refer to section
"Flue Liner Installation.")

4) Slide the unit half way into the fireplace.

5) Pull the vent connector plate through the tapered

brackets and fasten to the front plate. Refer to
section "Flue Liner Installation.")

6) Slide the unit fully into the fireplace. Level if

necessary.

7) Install 4-AA batteries into receiver or optional

AC power adaptor.

8) Test gas pressure (Refer to section "Gas Pipe

Pressure Testing"). Check aeration system
(Refer to section "Gas Insert Aeration System").

9) Install standard and optional features. Refer to

the following sections:

a. Brick Panels

b. Enamel Panels

c. Log Set

d. Glass Crystals

e. Spa stones

f. Low Profile Faceplate

g. Optional Screen

10) final check: Before leaving this unit with the

customer, the installer must ensure that the
appliance is firing correctly. This includes:

a) Clocking the appliance to ensure the correct

firing rate.

b) Adjusting the primary air, if required, to

ensure that the flame does not carbon. See

"Gas Insert Aeration System" section.

c) Ensuring that the appliance is venting

correctly.

MiniMuM Fireplace

dimensions

The minimum fireplace clearances & dimensions
for the Regency gas insert are shown in the
following diagrams:

Max Lentil

Bar Depth

A

Height

B

Depth

C

Width

(rear)

D

Width

(front)

E

Low

Profile

Faceplate

10"

20"

15.75"

22"

30"