L390E-2 / HZI390E-2 Direct Vent Gas Insert

installation

wiring diagraM

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.

(Do not cut the ground terminal off under any circumstances.)

Proflame System

Configuration

886 GTMF

Wire Diagram

0.880.001

Profl ame System
Confi guration
885 ON/OFF
Illustrated wire diagram

0.584.907

prOFlaMe reMOte systeM gtM (l390e / HZi390e)

SureFire™ Switch

cautiOn: label all wires prior to disconnection

when servicing controls. Wiring errors can

cause improper and dangerous operation.

Caution: ensure that the wires do not touch any

hot surfaces and are away from sharp edges.

gtm Remote sYstem - impoRtant: The AA batteries in the receiver operate the unit. If the batteries become weak, they will need

to be replaced with quality AA alkaline batteries. The unit will not operate without AA batteries.

Thermostat

(Optional)

See optional wall thermostat
installation in this manual.