L390E-2 / HZI390E-2 Direct Vent Gas Insert

installation

caution

Do not wire millivolt

thermostat wires

to 120v wire.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50 Ft.

16 GA.

32 Ft.

18 GA.

20 Ft.

20 GA.

12 Ft.

22 GA.

9 Ft.

OptiOnal wall tHerMOstat installatiOn

This installation must be completed during initial install with the side access panel removed.

A wall thermostat may be installed if desired.
Recommended: Mount thermostat beside unit receiver.

1) Run wires from thermostat into the unit using the appropriate wire gauge - see chart below.

3) Connect one thermostat lead to female connector, using male spade con-

nector - see pic below.

4) Connect one thermostat lead to male connector using female spade con-

nector - see pic below.

When complete turn remote receiver to the ON position.
Unit will now operate using the wall thermostat.

2) Remove the green wire marked (TH) at the white connector - shown
below.

Disconnect TH wire