beautypg.com

Installation, Standing pilot, Heat exchange return – Regency Liberty L390EB Medium Gas Insert User Manual

Page 34

background image

34

L390E-2 / HZI390E-2 Direct Vent Gas Insert

installation

The L390E / HZI390E use a heat exchanger and efficient combustion
technology to provide extreme heating efficiencies. The more efficient an ap-
pliance becomes, the lower the flue gas temperatures becomes.
On start-up, flue temperatures are required to initiate venting action.

Here are some considerations when setting up the L390E / HZI390E:

1) When operating the unit in temperatures below 50

° F, run the pilot in

"Standing Pilot" mode, by setting the Surefire™ switch to ON.

The switch is located to the bottom left of the Firebox Door.

Move the switch to the right to run in Standing Pilot mode, to the left to

run in Intermittent Pilot (electronic ignition) mode. This will aid in keeping
the flue slightly warmer than the outside air, making start up a smoother
process.

standing pilOt

Standing

Pilot On/Off

Exhaust Baffle

Screws help to locate

the Exhaust Baffle when

installing in the Firebox

Exhaust Baffle

Exhaust Baffle Screws (both sides)

Exhaust Baffle

Screw

Heat Exchanger Return

Heat Exchanger Return

adding tHe Heat excHanger return

1) Remove the panels if they are already installed. Remove one screw

in the upper left and upper right of the firebox. If the unit has been
previously operated, spray these screws with WD-40. Once the screws
have been removed, lower the front edge of the exhaust baffle and pull
towards you. There are 3 screws at the rear of the exhaust baffle that
help to position the baffle and keep it straight during operation.

2) Install the heat exchange return as shown.

3) Reinstall the exhaust baffle.

Surefire switch for standing pilot

Heat excHange return

note: Only installed at elevations of 35 feet or higher.

This manual is related to the following products: