INSTALLATION

NOTE: Wiring schematics for P36E-4 (120 Volts),
plug-in fan circuit with speed control switch on wall.

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(for mobile home)

Star washer

Ground

Green

Neutral

Live

Black

Red

Red

Fan Thermodisc

(normally open)

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

OPTIONAL FAN WIRING DIAGRAM

INSTALLING THE OPTIONAL FAN (INSTALLED UNIT)

120 Volt AC power is needed for the fan switch and blower. The fan can be
hard wired if desired. The grounded duplex receptacle should be installed
into the supplied receptacle box by a qualifi ed electrician. The neutral (wider)
slot of the polarized receptacle should be at the top.

Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.

1. Shut the power off.

2. Remove Flush door (See instructions in this Manual).

3. Remove inner panels (See instructions in this Manual).

4. Remove glass crystals or ceramic stones.

5. Remove the base tray by removing 6 screws in the locations shown

below.

Diagram 1: Remove the 6 screws and then lift

out the base tray

Diagram 2

6. Remove 2 screws in location shown below - slide burner to the right

then lift out. (See Diagram 2.