beautypg.com

Installation, Rigid pipe venting arrangements, Vertical terminations (propane & natural gas) – Regency Horizon HZ33CE Small Gas Fireplace User Manual

Page 21

background image

Regency HZ33CE Gas Fireplace

21

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS

Vertical Terminations

(Propane & Natural Gas)

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90

o

elbow, with rigid pipe

vent systems for Propane and Natural Gas.

• Unit must be raised 1".
• Firestops are required at each fl oor level and whenever passing through a wall.
• Maintain clearances to combustibles.
• Vent must be supported at offsets.

Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994..