beautypg.com

Installation, P q o n, Framing dimensions – Regency Horizon HZ33CE Small Gas Fireplace User Manual

Page 14: Gh i j

background image

14

Regency HZ33CE Gas Fireplace

INSTALLATION

M

L

K

P Q

O

N

Opening for gas

connection

J

I

Floor

DETAIL N

SCALE 1 : 6

2X4 HEADER

N

Non-combustible

Header

(steel stud

on edge)

G

H

I

J

Framing Dimensions

Description

HZ33CE

G

Framing Width

35"(889mm)

H

Framing Height *

31-3/4" (806mm)

I

Framing Rise from Floor

0" (when not using a surround)

2" min (when using Mantel)

3-5/16" min (when using 4 sided Faceplate)

J * For Finish with Tile

Surround

Framing Depth Vertical
Horizontal

22-3/4" (578mm) Vertical Rise

19-3/4" (502mm) Rigid / 16" (406mm) Flex

K

Corner Wall Length

38-15/16" (988mm)

L

Corner Facing Wall Width

55-1/2" (1410mm)

M

Framed Chase Ceiling*

36" (914mm) Rigid

32" (812mm) Flex

N

Vent Centerline Height*

30" (762mm) Rigid

26" (660mm) Flex

O

Gas Connection Height*

1 1/2" (38mm)

P

Gas Connection Inset*

7-3/16" (183mm)

Q

Gas Connection Width*

3" (76mm)

FRAMING DIMENSIONS

NOTE: If this is an outside corner, the

minimum distance between the vent
and the outside corner is 6" (15cm)
with AstroCap termination cap or 12"
(30cm) with Rigid Vent termination
cap.

(For example Dura-Vent)

* Measured from base of unit.