Installation, Clearances – Regency Horizon HZ33CE Small Gas Fireplace User Manual

Page 10

background image

10

Regency HZ33CE Gas Fireplace

INSTALLATION

Caution Requirements

The top, back and sides of the fi replace are defi ned by

standoffs. The metal ends of the standoff may NOT

be recessed into combustible construction.

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not

adhered to. It is of greatest importance that this fi replace and vent

system be installed only in accordance with these instructions.

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.

C

F

G

Clearance:

Dimension

Measured From:

A: *Front Floor Clearance (min.)

0"

Underside of Unit

B: *Sidewall (on one side)

9" (229mm)

Side Opening of Unit

C: *Ceiling
(room and/or alcove)

30" (762mm)

Top Opening of Unit

D: Alcove Width

84" (1219mm)

Sidewall to Sidewall (Minimum)

E: Alcove Depth

36" (914mm)

Front to Back Wall (Maximum)

F: Mantel

12" (305mm)

G: Mantel Clearances

15-3/4" (400mm)

From Top Opening of Unit

C

Close to Ceiling

Flue Clearances

Horizontal - Top

2-1/2"

Horiztonal - Side

1-1/2"

Horiztonal - Bottom

1-1/2"

Vertical (Flex Vent)

1-1/2"

Vertical (Rigid)

1-1/4"