Installation, Regency, Direct vent flex system – Regency Horizon HZ33CE Small Gas Fireplace User Manual

Page 17: Alternate horizontal termination caps

background image

Regency HZ33CE Gas Fireplace

17

INSTALLATION

Wherever necessary due to
external location of cap, the
AstroCap can be replaced
with the FPI Riser Vent Ter-
mination Cap.

REGENCY

®

DIRECT VENT FLEX SYSTEM

Horizontal Terminations Only

This venting system, in combination with the HZ33CE-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey.

The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .

Regency

®

Direct Vent Flex Termination Kit (Part # 946-513. includes all the parts needed to install the HZ33CE with a maximum run of 2 feet. If

installing the HZ33CE-4 with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-516 (10 ft) or

see "Rigid Pipe Venting Systems" Section for alternate venting arrangements.

MINIMUM

FLEX KIT CENTER-LINE

MINIMUM

RIGID PIPE CENTER-LINE

AstroCap Flex Kits

1

6-7/8" dia. fl exible liner (kit length)

2

4" dia. fl exible liner (kit length)

3

spring spacers (3.

4

thimble (2.

5

AstroCap termination cap (1.

6

screws (12.

7

tube of Mill Pac (1.

8

plated screws (8.

9

screws #8 x 1-1/2" drill point,
stainless steel (4.

Notes:
1. Liner sections should be continuous

without any joints or seams.

2. Only Flex pipe purchased from Regency

®

may be used for Flex installations.

Alternate

Horizontal

Termination

Caps

Note: - Unit must be raised by 1".