beautypg.com

Installation, Rigid pipe venting systems, Alternate horizontal termination caps – Regency Horizon HZ33CE Small Gas Fireplace User Manual

Page 18

background image

18

Regency HZ33CE Gas Fireplace

INSTALLATION

Pipe Length

Vertical

Terminal

Storm Collar

Flashing

Ceiling Firestop

Adj.Pipe Length

11" - 14-5/8”

90 Elbow

o

Horizontal

Termination Cap

# 946-523/P

Wall Thimble

Vinyl Siding

Standoff (Optional)

Rigid Pipe Adapter

# 510-994

45 Elbow

o

Pipe Length

Horizontal

Termination Cap

#946-523/P

Wall Thimble

Vinyl Siding

Standoff (Optional)

Pipe Length

The minimum components required for a basic
horizontal termination are:

1 AstroCap Horizontal Termination Cap
1 45

o

Elbow

1 Rigid Pipe Adaptor
1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

For siding other than vinyl, furring strips may
be used, instead of the vinyl siding standoff, to
create a level surface to mount the vent terminal.
The Terminal must not be recessed into siding.

If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2 inches.

This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.

WARNING:

Do not combine venting components from
different venting systems.

Exception: However, use of the the AstroCap

TM

and FPI Riser is acceptable with all systems.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

Alternate

Horizontal

Termination

Caps

Flat Wall Installation

Max. Wall Vent Length
Thickness (inches) Required (inches)
7 - 1/4"

6"

10 - 1/4"

9"

13 - 1/4"

12"

8 -1/4" 3" to 7" Slip

3" to 14-1/2 " Slip

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent,

American Metal Products Ameri Vent Direct Vent, Security Secure Vent

®

, Selkirk Direct-Temp. AstroCap

TM

is a proprietary trademark of FPI Fireplace

Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

13 - 1/4"

19-3/4"

(502mm)

27"

(686mm)