FPI FP90 Wood Fireplace
8
INST
ALLA
TION
38"
43- 5/8"
14- 5/8"
13-3/8"
28"
9-5/8"
25"
15"
4-3/4"
50- 1/2"
(1283mm)
42- 5/8"
3-5/8"
1-3/8"
7-7/8"
29-1/8"
31"
37-3/8"
(1083mm)
(92mm)
(121mm)
(965mm)
(1108mm)
(371mm)
(371mm)
(949mm)
(787mm)
(740mm)
(200mm)
(35mm)
(244mm)
(381mm)
(635mm)
(711mm)
Unit Dimensions
The Regency is a wood burning fireplace featuring
a self-contained heat-circulating system and cast-
iron doors with large viewing windows. A set of
andirons are installed in the firebox to properly
position the fire, do not remove them.
note: illustrations shown reflect “typical”
installations with nominal dimensions
and are for design and framing
reference only. actual installations
may vary due to individual design
preferences. However, always maintain
minimum clearances to combustible
materials and do not violate any
specific installation requirements.
diMensions and specifications
This fireplace system is designed for installation
in accordance with the National Fire Protection
Standard for chimneys, fireplaces and solid fuel
burning appliances; NFPA 211 and in accordance
with codes such as the BOCA Basic National
Codes, the Standard Mechanical Code, Uniform
Building Codes or applicable local codes.
failure to use parts
Manufactured BY fpi fireplace
products international, ltd.,
or Variations in tecHniQues
and construction Material
descriBed in tHis Manual,
MaY create a fire HaZard and
Void reGencY’s WarrantY.
The FP90 main unit consists of the following:
1) The main fire box and heat exchanger
2) Double doors with ceramic glass
3) Vermiculite side panels and baffle
4) The insulated outside air duct
5) Hearth Safety Strip
6) 1" unit base stand-offs
installation
The Regency fireplace has been tested and listed
by OMNI Test Laboratories, Inc. to ULCS610
Standard for Canada installations.
this unit
is intended for installation in conventional
homes and buildings of conventional
construction, not in mobile homes.
7) Nailing Strips