beautypg.com

Installation, Installation measurements / framing details, Inst alla tion – Regency Excalibur EX90 Large Wood Fireplace (Canadian Edition) User Manual

Page 13

background image

FPI FP90 Wood Fireplace

13

INST

ALLA

TION

installation MeasureMents / fraMinG details

installation

3" (76mm)

STAND-OFF

2x4 FRAMING
FRONT OF UNIT ONLY

COMBUSTION AIR

TO OUTSIDE

38"

(965mm)

19"

(483mm)

30"

(762mm)

60" (1524mm) WIDE INSIDE MIN.

UNIT TO BE CENTERE

NOTE:
FRAMING TO BE AGAI
STAND-OFFS ONLY

11"

(279mm)

D

NST

24"

(610mm)

VENT TO OUTSIDE

COMBUSTION AIR

11"

(280mm)

HEARTH MUST HAVE 1/2" (127mm)

MILLBOARD UNDER FINISH MATERIAL

WITH MIN. "K" FACTOR OF 20.07

50 3/4"

(1289mm)

44"

(1118mm)

40"

(1016mm)

18"

(457mm)

46"(1168mm)

MIN.

11"

(280mm)

18"

(457mm)

2X4,

2X6,

2X8

ON

END

60"(1524mm)

WIDE INSIDE CHASE MIN.

10"

(254mm)

84" (2134mm)

CEILING

NOTES:
1) CHASE MUST BE 60" (1524mm) WIDE INSIDE AND UNIT TO BE CENTERED IN OPENING.
2) MANTEL MIN. HEIGHT OF 18" (457mm) FROM TOP OF LOUVER OPENING TO UNDERNEATH MANTEL or 55 1/2" (1410mm) FROM BOTTOM OF UNIT.
3) MUST HAVE NON-COMBUSTIBLE MATERIAL EXTENDING 11" (280mm) ON EITHER SIDE AND 9" (229mm) ON TOP. 3/8" (10mm) THICK FINISHING

MATERIAL TO BE INSTALLED ON TOP OF THIS.

4) FRAMING IS SLIGHTLY LARGER THAN UNIT DIMENSIONS TO ALLOW FOR EASIER INSTALLATION (50 3/4", 1289mm H x 44", 1118mm W)
5) MUST MAINTAIN A MIN. OF 46" (1168mm) FROM TOP OF LOUVER OPENING TO FINISHED CEILING.
6) MUST MAINTAIN A MIN. OF 24" (610mm) TO SIDE WALL FROM THE EDGE OF THE TOP LOUVER OPENING.
7) HEARTH MUST BE A MIN. OF 40" (1016mm) WIDE x 18" (457mm) deep and 1/2" (127MM) THICK.

2x4

2x4