6) Use solid fuel only. DO NOT use artificial logs

containing petroleum products, chemical

chimney cleaners, gas logs, gas lighters,

salt contaminated wood or flame colorants

in your fireplace. When using compressed

sawdust logs use only at 1/3 capacity since

these get very hot and expand.

7) DO NOT use charcoal or coal under any

circumstances.

8) NEVER use gasoline, gasoline-type lantern

fuel, kerosene, charcoal lighter fluid, or any

liquid to start or “freshen up” a fire in this

fireplace. Keep any flammable liquid a safe

distance from the fireplace.

9) Ashes should be placed in a metal

container with a tight-fitting lid. The closed

container of ashes should be placed on a

non-combustible floor or on the ground,

well away from all combustible materials,

pending final disposal. If the ashes are

disposed of by burial in soil or otherwise

locally dispersed, they should be retained

in the closed container until all cinders have

thoroughly cooled.

10) WarninG: only operate fireplace with

doors fully open when optional fire screen

is used.

11) neVer leave children unattended when

there is a fire burning in the fireplace.

12) Allow the fireplace to cool before servicing.

Always shut-off any electricity to the fireplace

while working on it. This will prevent any

possible electrical shock.

13) regency is not responsible for any

smoking or related problems that

may result from the lack of adequate

combustion air. it is the responsibility

of the installer to ensure that adequate

combustion air has been provided for

the fireplace.

read Before You install

tHe reGencY HiGH

efficiencY epa certified

fireplace

This installation manual will enable you to make

a safe, efficient and dependable installation of

your fireplace and chimney system. Please

read and understand these instructions before

beginning your installation.

Do not alter or modify the fireplace or its

components under any circumstances. Any

modification or alteration of the fireplace system,

including but not limited to the fireplace, chimney

components and accessories, may void the

warranty, listing and approvals of this system

and could result in an unsafe and potentially

dangerous installation.

please retain tHis Manual for

future reference.

iMportant: please read and follow these

rules for safety.

1) Before starting your fireplace installation,

read these installation instructions carefully

to be sure you understand them in their

entirety. Failure to follow them could cause

a fireplace malfunction resulting in serious

injury and/or property damage.

2) Always check with your local building

department, fire department and local

authorities prior to installation to determine

the need to obtain a permit.

3) This model fireplace must be installed with

one of the chimney systems listed in the

Chimney Section in this manual. These

systems are intended for use as a residential

type appliance. The chimney must always

vent to the outside of the building.

4) WarninG: tHis fireplace Has not

Been tested WitH an unVented

Gas loG set. to reduce risK of

fire or inJurY, do not install an

unVented Gas loG set into tHe

fireplace.

5) To ensure a safe fireplace system and to

prevent the build-up of soot and creosote,

inspect and clean the fireplace and chimney

prior to use and periodically during the

heating season.

14) FPI Fireplace Products International Ltd.

does not warranty “smoke-free” operation

nor are we responsible for inadequate

system draft caused by mechanical systems,

general construction conditions, inadequate

chimney heights, adverse wind conditions

and/or unusual environmental factors or

conditions beyond our control.

15) iMportant: Check with your local building

department as to the requirements of sealing

any penetrations to the exterior. This will

ensure that the integrity of the building is

intact.

16) do not use a fireplace insert or any other

product not specified by Regency for use

with this fireplace.

17) neVer, under any circumstances, install

a fireplace, chimney component or any

accessories, supplied by Regency, that have

visible or suspected physical damage as a

result of handling or transportation. These

items should be inspected by a Regency

dealer or qualified factory representative

to ensure safe condition. When in doubt,

consult your Regency dealer.

18) It is recommended that power is supplied

to the terminal block of the unit to allow for

the installation of blower components now

or at a future date.

emissions from burning wood or gas

could contain chemicals known to the

state of california to cause cancer, birth

defects or other reproductive harm.