background image

FPI FP90 Wood Fireplace

34

HEA

TW

A

VE KIT

HeatWaVe Kit (not epa approVed)

Diagram 4

4) Install the variable speed Wall Rheostat (with

OFF setting) in a convenient location. This

switch controls the fan operation.

5) Wire 120V AC service to the Wall Rheostat

and from the Wall Rheostat to the Fan

Junction Box. Use wire nuts to secure the

120V AC wires to the hot and neutral fan

wires and screw the 120V AC ground wire

to the Fan Junction Box. See wiring diagram

below.

6) Screw the fan junction box to the fan

housing.

7) Screw the Register Adapter Frame and the

Air Register to the Fan Housing, diagram 4

below.

oval air duct: Attach the round-to-oval

adaptor to the fireplace starting collar and

a 6" oval duct (not supplied) to the adaptor.

Complete the duct run and attach the oval

duct to the fan housing.

round and oval duct: A combination of

6" round and 6" oval duct can be used in

the duct run. Oval duct components are

not supplied but can be purchased from an

HVAC supplier.

operation

1) Start the fireplace as per instructions and

allow it to warm up.

2) Turn the Wall Rheostat "ON" and adjust the

variable speed based upon desired air flow

at the Air Duct Register.

Maintenance

1) Service and maintain the fireplace as per

the fireplace installation manual.

2) Keep the Air Register(s) clean and free of

any blockage.

note: for new construction only the

air register is required to cover the

opening.

8) Complete the fireplace installation as per

fireplace installation manual.

Ground Lug

caution: label all wires prior

to disconnection when servicing

controls. Wiring errors can

cause improper and dangerous

operation.

caution: ensure that the wires do

not touch any hot surfaces and are

away from sharp edges.

note: The wires (in dotted lines) and

wire nuts are supplied by others.

iMportant: if the internal blower is installed, it cannot be operated if the Heat Wave air duct kit fan is operating.

WirinG diaGraM

do not cut the ground terminal off

under any circumstances.

Diagram 3