Safety label for fp90, Safety label, Fpi fp90 wood fireplace 5 – Regency Excalibur EX90 Large Wood Fireplace (Canadian Edition) User Manual
Page 5: Duplicate serial
FPI FP90 Wood Fireplace
5
SAFETY LABEL
safetY laBel for fp90
This is a copy of the label that accompanies each Regency Fireplace.
It is located inside the lower louver opening on the left side. We have
printed a copy of the contents here for your review.
safetY laBel
note: Regency units are constantly being improved. Check the label
on the unit and if there is a difference, the label on the unit is the correct
one.
LISTED
F
ACT
OR
Y
BUIL
T
FIREPLACE
FPI
WOOD
FIREPLACE
MODEL:
FP90
DO
NOT
REMOVE
THIS
LABEL
Serial
Number
Duplicate
Serial
#
MINIMUM
CLEARANCES
T
O
COMBUSTIBLE
MA
TERIALS
Side
W
all
24
in.
/610
mm.
From
edge
of
top
vent.
Mantel
18
in.
/457
mm.
From
top
of
vent.
Unit
T
op,
Back,
Sides
and
Bottom
0
in.
/
0
mm.
T
o
standof
f
Hearth
Extension
40
in.
/1016
mm.
Wide
18
in.
/457
mm.
Depth
Mantel
Projection
10
in.
/254
mm.
From
face.
MINIMUM
CLEARANCES
T
O
COMBUSTIBLE
MA
TERIALS
Side
W
all
18
in.
/457
mm.
From
edge
of
top
vent.
Mantel
18
in.
/457
mm
From
top
of
vent.
Unit
T
op,
Back,
Sides
and
Bottom
0
in.
/0
mm.
T
o
standof
f
Hearth
Extension
40
in.
/1016
mm.
Wide
18
in.
/457
mm.
Depth
Mantel
Projection
10
in.
/254
mm.
From
face.
FPI
Fireplace
Products
International
Ltd.
Delta,
BC,
Canada
MANUFACTURED
918-424g
MADE
IN
CANADA
2009
2010
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
287
287
Install
and
use
only
in
accordance
with
the
manufacturer's
installation
and
operating
instructions.
TESTED
T
O
:
ULC-S610-M87
REPOR
T
No.
219-S-10-2
T
E
S
T
E
D
T
O
:
U
L
-1
2
7
R
E
P
O
R
T
N
o
.2
1
9
-S
-1
0
b
-2
IN
CANADA
IN
USA
OPTIONAL
COMPONENTS:
Ashdrawer
,
Flue
Adaptor
8-7
in.,
Fan,
Surround
Black,
Surround
Polished
Gold,
Surround
Antique
Nickel,
Louver
Flush
Black,
Louver
Flush
Black/Gold,
Louver
Flush
Black/Steel,
Surround
Accent
Gold
Excalibur
,
Surround
Accent
Nickel
Excalibur
,
W
ood
Screen,
Finishing
T
rim,
Masonry
Retainer
Kit,
Heatwave
Kit
and
Gravity
Kit.
OPTIONAL
COMPONENTS:
Ashdrawer
,
Fan,
Surround
Black,
Surround
Polished
Gold,
Surround
Antique
Nickel,
Louver
Flush
Black,
Louver
Flush
Black/Gold,
Louver
Flush
Black/Steel,
Surround
Accent
Gold
Excalibur
,
Surround
Accent
Nickel
Excalibur
,
W
ood
Screen,
Finishing
T
rim,
Masonry
Retainer
Kit,
Gravity
V
ent
Kit
and
Air
Cool
Pipe
Adaptor
.
COMPONENTS
REQUIRED
FOR
INST
ALLA
TION:
-
Non-combustible
floor
protection
of
1/2”
(13mm)
thick
material
wit
h
a
minimum
k-factor
of
20.07
is
required
extending
18”
(457mm)
to
the
front
and
8”
(203mm)
to
the
sides
of
the
feed
door
.
See
installation
manual.
-
Use
6”
(152
mm)
diameter
insulated
flexible
duct
and
combustion
air
inlet
assembly
.
-
Use
one
of
the
following
7
”
(178mm)
or
8”
(203mm)
listed
ULC-S629
chimney
’s
:
SELKIRK
CF
SENTINAL,
SUPER
VENT
2100,
SUPER
PRO
2100,
SECURITY
SECURE
TEMP
S-2100+,
OLIVER
MACLEOD
PROJET
NOV
A
HT6000+,
SIMPSON
DURA-VENT
DURA
PLUS
HTC,
ICC
EXCEL
2100.
COMPONENTS
REQUIRED
FOR
INST
ALLA
TION:
-
Non-combustible
floor
protection
of
1/2”
(13mm)
thick
material
wit
h
a
minimum
k-factor
of
0.84
is
required
extending
18”
(457mm)
to
the
front
and
8”
(203mm)
to
the
sides
of
the
feed
door
.
See
installation
manual.
-
Use
6”
(152mm)
diameter
insulated
flexible
duct
and
combustion
air
inlet
assembly
.
-
One
cooling
air
vent
(see
installation
instructions
for
details).
-
Use
one
of
the
following
8
”
(203mm)
diameter
listed
air
cooled
chimney
systems,
complete
with
components
as
specified
by
the
manufacturer:
Majestic
SK8,
Security
FTF8,
Superior
TF8,
Simpson
DuraV
ent
Dura-Plus.
FOR
USE
WITH
SOLID
WOOD
FUEL
ONL
Y
.
Do
not
overfire
the
fireplace.
Operate
only
with
viewing
doors
fully
closed
or
fully
open
when
optional
fire
screen
is
used.
Firebricks
must
be
in
place
during
operation.
Combustible
materials
are
not
permitted
on
face
of
unit.
Do
not
obstruct
combustion
air
inlet.
Do
not
us
e
a
fireplace
insert
or
other
products
not
specified
for
use
with
this
product.
This
fireplace
has
not
been
tested
with
an
unvented
gas
log
set.
T
o
reduce
risk
of
fire
or
injury
,
d
o
not
install
an
unvented
gas
log
set
into
the
fireplace.
Replace
glass
only
wit
h
5
m
m
neoceramic
glass.
Electric
rating.
1
15
V
-
60H
z
-
1.2
AMPS
FOR
USE
WITH
SOLID
WOOD
FUEL
ONL
Y
.
Do
not
overfire
the
fireplace.
Operate
only
with
viewing
doors
fully
closed
or
fully
open
when
optional
fire
screen
is
used.
Firebricks
must
be
in
place
during
operation.
Combustible
materials
are
not
permitted
on
face
of
unit.
Do
not
obstruct
combustion
air
inlet.
Do
not
us
e
a
fireplace
insert
or
other
products
not
specified
for
use
with
this
product.
This
fireplace
has
not
been
tested
with
an
unvented
gas
log
set.
T
o
reduce
risk
of
fire
or
injury
,
d
o
not
install
an
unvented
gas
log
set
into
the
fireplace.
Replace
glass
only
wit
h
5
m
m
neoceramic
glass.
Electric
rating.
1
15
V
-
60H
z
-
1.2AMPS
(Refer
to
Manual)
2011
UNITED
ST
A
TES
ENVIRONMENT
AL
PROTECTION
AGENCY
CERTIFIED
T
O
COMPL
Y
WITH
JUL
Y
1990
P
ARTICULA
TE
EMISSION
ST
ANDARDS