Opticon OPN 2001 Device Parameters User Manual
Page 2

Opticon OPN2001 User Parameters
Page 2 of 3
There are no barcode changeable parameters in the OPN2001; they are only changeable by host command.
Parameter
Comments
Min/Max Values
Default
Param Num
Buzzer
1=Enable
0=Disable
Enabled
2 (0x02)
Reject Redundant
Barcode
Disabling will allow same
barcode to be stored
consecutively.
Mode 1 means that a code is
allowed only if the previous code
is not the same.
Mode 2 means that a code is
allowed only if none of the
previous codes are the same.
2=Enable mode 2.
1=Enable mode 1.
0=Disable
Disabled
4 (0x04)
Low-Battery Indication
Determines how low battery
condition will be handled.
0=No operation
1=Ignore low battery
2=Indicate, but laser
stays off
3=Indicate, operate
normal otherwise.
3
7 (0x07)
Code128
1=Enable
0=Disable
Enabled
8 (0x08)
UPC & EAN
1=Enable
0=Disable
Enabled
9 (0x09)
Host Connect Beep
1=Enable
0=Disable
Enabled
10 (0x0a)
Host Complete Beep
1=Enable
0=Disable
Enabled
11 (0x0b)
Auto Clear
Clear barcodes after upload.
1=Enable
0=Disable
Disabled
15 (0x0f)
Scanner
On-Time
1 sec. – 10 sec. in 100
msec increments
30 (3.0 sec) 17 (0x11)
RSS code
0 = Disable
1 = RSS Limited
2 = RSS 14
4 = RSS Expanded
(Options can be
combined)
0
20 (0x14)
Good Decode LED On
Time
250 ms. – 1 sec. in
250msec. Increments
4
(1.0 sec)
30 (0x1e)
Code 39
1=Enable
0=Disable
Enabled
31 (0x1f)
Delete Enable
Determines operation of the
Delete key, the Clear All and Set
All Default functions.
Bit 0 = Clear all
Bit 1 = Delete key
Bit 2 = Set all Default
e.g. 5 = Clear all enabled,
Set all Default enabled,
Delete key disabled.
7 =
Delete
Enabled
Clear All
Enabled
Set Default
Enabled
33 (0x21)
Max Barcode Len
1 – 30
30
34 (0x22)
Store RTC timestamp
Store Real Time Clock data
1=Enable
0=Disable
Enabled
35 (0x23)