Unit
Multi-Pump Control Manager
Operation
25
3
Run/Stop/Bypass
Pushbutton/Indicator. Pushbutton used to start and stop the
HPU.
Run - gray. black letters: In this state, press to start the HPU.
Stop - gray, red letters: In this state, press to stop the HPU.
Bypass - blue, white letters: In this state, press to start the
HPU in bypass mode. The Faulted state will turn to
Overtemp Bypass. Bypass mode only occurs during an
overtemperature condition and allows the HPU to run in low
pressure to cool the hydraulic fluid. An internal timer allow
the bypass mode to run for five minutes. It might be
necessary to repeat activating the bypasss mode several times
before fluid temperature is within an acceptable range,
In remote operation, the run and bypass buttons are disabled.
4
High Pressure
Pushbutton/Indicator. Used to put the HPU in high pressure
or return to running; pushbutton acts as a toggle between the
two modes.
High Pressure - gray: indicates the HPU is not in high
pressure.
High Pressure - green: Directs the HPU to sequence to high
pressure. When the HPU is in high pressure it will be
indicated on the main display.
In remote operation, the High Pressure button is disabled.
5
Local/Remote DIO/Remote ENET
Indicators. Used to indicate which method is being used to
control the HPU.
Note
The unit must be in Remote ENET to operate with
the MPCM. This can only be changed at the HPU.
6
Auto
Pushbutton/Indicator. Change between manual mode and
auto mode. Auto mode will start the modules with the lowest
hours first until the demand is satisfied.
Auto - gray: Indicates the HPU is in manual mode.
Auto- green: Indicates the HPU is in auto mode.
When using the auto mode, you need to set the flow demand.
Push the associated value pushbutton below the Flow
Demand title to display the keypad. With the keypad
displayed, use the number keys to set the desired flow level
and then press Enter to set the value and return to the Main
screen.
7
ROD (Run On Demand)
(optional)
Pushbutton/Indicator. Used to automatically control pump
operation as system demand changes. The ROD button is
only shown when in auto mode.
ROD - gray: Indicates Run On Demand is not enabled.
ROD- green: Indicates Run On Demand is enabled.
Item
Name
Description