Maintenance and troubleshooting, Cooling flow, Return to mk diamond for repair – MK Diamond MK-2000 User Manual
Page 35

MK-2000
Revision 03/05, Effective Date March 21, 2005
Page 35
MAINTENANCE AND TROUBLESHOOTING
5. Cooling Flow:
(A)
Check Cooling Flow Adjusting
Valve open
(C)
Place Pump into a bucket of
water and check flow
(B)
Remove the Cooling Transfer
Tube from the Blade Guard inlet
(D)
Remove the Cooling Transfer
Tube and check flow
(E)
Remove the Pump Discharge
Fitting and check
(F)
Remove the Pump Intake
Screen and check for debris
Go to
Step C
If flow exist,
go to Step E
Pull Tab
to loosen
If flow exists,
go to Step A
Pull to
Remove
If flow exists,
go to Step F
Remove
Discharge Fitting
If Screen clean,
go to Step G
(E)
Check power source voltage is
115V (240v if running at 240v)
– if not 115v move to another
circuit
(D)
Verify Circuit Breaker is not
tripped; if tripped, reset the
Circuit Breaker once
If circuit breaker
not tripped go to
Step F
Check Breaker
tripped
If circuit breaker
not tripped go to
Step F
Check for
correct circuit
voltage
If tripped, reset
once if trips again,
go to step F
Return to
MK Diamond
for Repair
(F)
Return to MK Diamond
Pull to
Remove
If flow exists,
go to Step D
Cover Pump
Suction with
water
Pull Intake Screen
to remove