12 signal configuration, 1 drive and motor interface, 9400 technology applications | table positioning – Lenze E94AxHE Technology Application Table positioning User Manual
Page 36
![background image](/manuals/566323/36/background.png)
9400 Technology applications | Table positioning
Parameter setting & configuration
Signal configuration
36
L
EDS94TA10050xxxx EN 1.2 - 03/2010
5.12
Signal configuration
5.12.1
Drive and motor interface
If required, the preset signal configuration of the control and setpoint inputs of the drive
and motor interface can be easily reconfigured by parameterising the assigned multiplexer
parameters.
Drive interface
Motor interface
Signal (Lenze setting)
Control input
Signal configuration
FALSE Set controller inhibit
C03130/1
DIGIN 5 Reset error 1
C03130/2
Control word 1 bit 07 Reset error 2
C03130/3
FALSE Reset error 3
C03130/4
FALSE Set error
C03130/5
Control word 1 bit 00 Switch on drive
C03130/6
Signal (Lenze setting)
Setpoint input
Signal configuration
100 % Load position controller
adaptation
C03141/1
100 % Motor position controller
adaptation
C03141/2
100 % Speed controller adaptation
C03141/3
100 % Upper torque limit value
C03141/4
-100 % Lower torque limit value
C03141/5
100 % Flux setpoint
C03141/6
100 % Mass inertia adaptation
C03141/7