6 "teach" function, Deceleration and s-ramp times, Teach" function – Lenze E94AxHE Technology Application Table positioning User Manual
Page 26: 9400 technology applications | table positioning
9400 Technology applications | Table positioning
Parameter setting & configuration
Profile data management
26
L
EDS94TA10050xxxx EN 1.2 - 03/2010
5.4.6
"Teach" function
The "Teach" function of the profile data management enables the teaching of positions,
speeds, accelerations and S-ramp times.
The basic function "Manual jog" serves, for instance to approach the desired position
manually and transmits it via "Teaching" to the variable table for positions.
Parameter setting: Tab Application parameters dialog level Overview
L_PositionerTable
Control/setpoint inputs of the function
Signal configuration
Lenze setting
Control/setpoint input
(Multiplexer parameters)
FALSE Teach position
C03020/1
C03016 Selection of table position for position
C03029/1
Zero position Teach position
C03125/1
FALSE Teach speed
C03020/2
C03017 Selection of table position for speed
C03029/2
Speed setpoint Teach speed
C03024/1
FALSE Teach acceleration
C03020/3
C03018 Selection of table position for acceleration
C03029/3
0 Teach acceleration
C03027
FALSE Teach S-ramp time
C03020/4
C03019 Selection of table position for S-ramp time
C03029/4
0 Teach S-ramp time
C03028
Note!
After the function block editor is enabled the "Teach" function must be
configured directly in the FB interconnection instead of via the parameters
mentioned before!