Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for
the "Table positioning" technology application.
The default signal configuration if required can be easily changed by parameterising
the multiplexer parameters assigned.
Analog outputs
Digital outputs
Statebus
Display elements
Terminal X3
Signal (Lenze setting)
Signal configuration
AO1
Motor speed
• Scaling: ±10 V ≡ motor reference speed (C00011)
C03110/1
AO2
Motor torque (setpoint)
• Scaling: ±10 V ≡ Motor reference torque (C00057/2)
C03110/2
Terminal X4
Signal (Lenze setting)
Signal configuration
DO1
Status "Drive ready"
• DC-bus voltage is available and no error has occurred.
C03100/1
DO2
Status "Positioner active"
C03100/2
DO3
Status "Limitation active"
• At the moment a setpoint is limited or a software or hardware
limit switch has been reached.
C03100/3
DO4
Status "Error active acknowledgement is required"
• A monitoring function with the error response "Error" or "Quick
stop by trouble" has been activated and the controller is in the
status "Error active" or "Quick stop by trouble active".
C03100/4
Terminal X2
Signal (Lenze setting)
Signal configuration
SB
Status "Error active acknowledgement is required"
• A monitoring function with the error response "Error" or "Quick
stop by trouble" has been activated and the controller is in the
status "Error active" or "Quick stop by trouble active".
• The state bus is put in the "error" status.
C03100/5
User LED
Signal (Lenze setting)
Signal configuration
Status "Positioning enabled"
C03100/6