5.10
Brake control
[5-13] Basic function "Brake control" (schematic diagram)
If the automatic operation (operating mode 2 or 12) is selected in C02580, the brake is
controlled automatically, i.e. if the multi-purpose positioning or another basic function is
activated which causes the drive to traverse, the brake is opened automatically and the
operation is enabled.
Parameter setting: Tab Application parameters dialog level Overview Brake control
The basic function "Brake control" serves
to the wear free control and monitoring of
a holding brake.
In the simplest case, an optionally
available brake module is used.
Alternatively the holding brake can also be
controlled and monitored via the digital
inputs/outputs.
Status
machine
(basic drive
functions)
M
LS_Brake
Note!
In the Lenze setting the brake control is switched off to reach a safe state after
mains connection.
Parameter
Lenze setting
Value Unit
C02580
Operating mode of brake
Brake control off
C02581
Brake activation threshold
50 rpm
C02582
Brake response to pulse inhibit
Activate the brake immediately
C02583
Status input monitoring
Not active
C02585
Brake control polarity
Not inverted
C02586
Starting torque 1
0.00 Nm
C02587
Starting torque 2
0.00 Nm
C02588
Starting torque source
Starting torque 1/2
C02589
Brake closing time
100 ms
C02590
Brake opening time
100 ms
C02591
Waiting time - status monitoring
100 ms
C02593
Waiting time - brake activation
0.000 s
C02594
Test torque
0.00 Nm
C02595
Permissible angle of rotation
5 °
C02596
Grinding speed
100 rpm
C02597
Acc./dec. time - grinding
1.000 s
C02598
Grinding ON time
0.5 s
C02599
Grinding OFF time
0.5 s