Lenze 931W User Manual
Page 28

Electrical installation
Important notes
5
28
GHB 13.0002-EN 3.1
5
Electrical installation
5.1
Important notes
Stop!
The drive controller contains electrostatically sensitive components.
The personnel must be free of electrostatic charge prior to assembly and
service operations.
Danger!
ƒ
The connection of all pluggable terminals has to be effected in a
deenergised state.
ƒ
Connecting and disconnecting the voltage supply (X2) due to the charging
processes of the intermediate circuit capacitor may cause traces of burning
on the wrap connection, and may result in a destruction of the internal
electronic circuit.
ƒ
A false polarity of the DC supply can bring about the destruction of the
drive. Before switching the drive on, ensure that the polarity of the
DC supply is correct.
Note!
For trouble-free operation, the following conditions are required:
ƒ
An installation according to EMC.
ƒ
The shield of the motor cable has to be connected to PE potential as
extensively as possible to prevent effects due to interference.
ƒ
The resolver cable, encoder cable, and the motor cable may have a length of
10 m at a maximum!
ƒ
The feeding power supply units have to be sufficiently dimensioned. The
power supply units have to be protected against overcurrent by means of
appropriate input fuses.