2 technical data, General data, Technical data – Lenze EDK71MMXXX−020 User Manual
Page 79
Technical data
General data
2
EDK71MMXXX−020 DE/EN/FR 5.0
79
L
Conformity
CE
Low−Voltage Directive (2006/95/EC)
EMC Directive (2004/108//EC)
Standards
DIN EN 60947−4−2
Semiconductor motor control devices and starters for AC
voltage
Vibration resistance
Accelerational stability up to 4 g (Germanischer Lloyd, general requirements)
Climatic conditions
Class 3K3 to EN 50178 (without moisture condensation, medium relative
humidity 85
%)
Degree of pollution
VDE 0110 Part 2, Degree of pollution 2
Permissible temperature
ranges
Transport
−25 °C ... +70 °C
Storage
−25 °C ... +60 °C
Operation
with motor mounting: −25 °C ... +60 °C
with wall mounting: −25 °C ... +40 °C
Permissible installation
height
0 ... 4000 m amsl
Above 1000 m amsl Reduce rated output current by 5 %/1000 m .
Mounting positions
Every mounting position and mounting direction is permissible.
Free space
Above
100 mm
Lateral
100 mm
EMC
−18−
Maintaining requirements to EN 61800−3/A11
Noise emission
Maintaining limit class B to EN 60947−4−2
Leakage current toward PE
(to EN 50178)
< 3.5 mA
Enclosure
−19−
(only with rubber cap on AIF
interface)
IP 65
NEMA 250 Type 4
Protective measures against
Motor overtemperature (input for PTC or thermal contact, I
2
t monitoring)
Protective insulation of
control circuits
Safe disconnection from mains:
Double/reinforced insulation to EN 50178
Insulation resistance
Overvoltage category III to VDE 0110