Commissioning, Code table – Lenze EDK71MMXXX−020 User Manual
Page 131
Commissioning
Code table
7
EDK71MMXXX−020 DE/EN/FR 5.0
131
L
Code
IMPORTANT
Setting options
No.
Selection
Lenze
Designation
C0417
v
Configuration of
starttec status
messages (1)
Output of internal digital signals to bus
The assignment is mapped
to
l
starttec status word 1
(C0150)
l
FIF output word 1
(FIF−OUT.W1)
l
Output word 1 in CAN
object 1 (CAN−OUT1.W1)
1 Bit 0
1
Reserved
2 Bit 1
2
Reserved
3 Bit 2
3
Status of motor 1
4 Bit 3
4
Status of motor 2
5 Bit 4
5
Status of brake
6 Bit 5
6
Error in power section
7 Bit 6
7
Reserved
8 Bit 7
8
starttec released/inhibited
9 Bit 8
9
11|10|9|8 Device status
10 Bit 9
10
0011 Operation inhibited
11 Bit 10
11
0110 Operation released
12 Bit 11
12
1000 Active fault
13 Bit 12
13
Overtemperature" warning
14 Bit 13
14
Reserved
15 Bit 14
15
Reserved
16 Bit 15
16
Ready for operation
For possible internal digital signals
see C0415
C0418
v
Configuration of
starttec status
messages (2)
Output of internal digital signals to bus
The assignment is mapped
to
l
Drive controller status
word 2 (C0151)
l
FIF output word 2
(FIF−OUT.W2)
l
Output word 1 in CAN
object 2 (CAN−OUT2.W1)
1 Bit 0
255
Not assigned
... ...
...
16 Bit 15
255
Not assigned
Internal digital signals same as
C0415
C0423
Switch−on delay
of brake
0.00
0.00
{0.01 s}
20.00 Only affects brake output
X1/B1, B2
C0424
Switch−off delay
of brake
0.00
0.00
{0.01 s}
20.00