Commissioning, Code table – Lenze EDK71MMXXX−020 User Manual
Page 113
Commissioning
Code table
7
EDK71MMXXX−020 DE/EN/FR 5.0
113
L
Code
IMPORTANT
Setting options
No.
Selection
Lenze
Designation
C0002
s
uSEr
(Cont.)
Restore delivery
state
1
Lenze setting
ð
PAR1
Restore delivery state in the
selected parameter set of
the drive controller
2
Lenze setting
ð
PAR2
3
Lenze setting
ð
PAR3
4
Lenze setting
ð
PAR4
31
Lenze setting
ð
FPAR1
Restore delivery state in the
fieldbus function module
61
Lenze setting
ð
PAR1 + FPAR1
Restore delivery state in the
selected parameter set of
the drive controller and in
the fieldbus function
module
62
Lenze setting
ð
PAR2 + FPAR1
61
Lenze setting
ð
PAR3 + FPAR1
62
Lenze setting
ð
PAR4 + FPAR1
Transfer
parameter sets
with keypad
You can use the keypad to
transfer parameter sets to
other drive controllers.
During the transfer,
access to the parameters
via other channels is
inhibited!
Keypad
ð
drive controller
Overwrite all available
parameter sets
(PAR1 ... PAR4, if necessary
FPAR1) with the
corresponding data of the
keypad
70
with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
10
with all other function modules
Keypad
ð
PAR1 (+ FPAR1)
Overwrite the selected
parameter set and FPAR1, if
necessary, with the
corresponding data of the
keypad
71
with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
11
with all other function modules
Keypad
ð
PAR2 (+ FPAR1)
72
with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
12
with all other function modules