beautypg.com

4 electrical installation, Electrical installation – Lenze ECSCKxxx User Manual

Page 49

background image

Electrical installation

Wiring according to EMC (installation of a CE−typical drive system)

4

l

49

EDKCSCK002 DE/EN/FR 1.1

4

Electrical installation

4.1

Wiring according to EMC (installation of a CE−typical drive system)

General notes

ƒ

The electromagnetic compatibility of a machine depends on the type of
installation and care taken. Especially consider the following:

Assembly

Filters

Shielding

Earthing

ƒ

For diverging installations, the conformity to the CE EMC Directive requires a
check of the machine or system regarding the EMC limit values. This is valid,
for instance, when:

Using unshielded cables

Using collective suppression filters in place of the assigned RFI filters

Operation without RFI filter

ƒ

The compliance of the machine application with the EMC Directive is in the
responsibility of the user.

If you observe the following measures, you can assume that the machine
will operate without any EMC problems caused by the drive system and
that compliance with the EMC Directive and the EMC law is achieved.

If devices which do not comply with the CE requirement concerning noise
immunity EN 61000−6−2 are operated close to the axis modules, these
devices may be electromagnetically impacted by the axis modules.