Commissioning – Lenze E84DGFCG User Manual
Page 38

Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013
38
Commissioning
Establishing an online connection via EtherNet/IP with the Lenze »Engineer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In the »Engineer«, you can use the Online Set communication path and go online menu command
to select the EtherNet/IP communication path. The previously configured EtherNet/IP nodes are
shown in the "Communication path" dialog window:
If the device access path is not configured correctly, the
IP address of the drive selected in the
display field can be entered manually here.
Via the
Search/Enter button, you can establish a connection to devices which have not
appeared in the display field. Corresponding settings for this can be made in the "Enter IP Address"
dialog window that will appear:
Here you can enter an
IP address manually or execute the following actions using the buttons:
• Execute the console command
Ping.
• Assign the IP address via the
Configurator.
Setting via the EtherNet/IP configurator of the »Engineer«
• Select the device access path to the desired drive by clicking
Find.
After having established the online connection, you can continue work with the »Engineer« as
usual.