beautypg.com

12 error messages, 1 short overview of the profibus error messages, Error messages – Lenze E84AYCPM User Manual

Page 91

background image

12

Error messages

12.1

Short overview of the PROFIBUS error messages

91

Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12

Error messages

This chapter supplements the error list contained in the software manual and in the »Engineer«

online help for Inverter Drives 8400 by the error messages of the communication module.

12.1

Short overview of the PROFIBUS error messages

The following table lists all PROFIBUS error messages in numerical order of the error number.

Furthermore the preset error response and – if available – the parameters for setting the error

response are specified.

Tip!
When you click the cross-reference in the first column, you will see a detailed description

(causes and remedies) of this error message.

Software manual/online help for Inverter Drives 8400
Here you can find general information on diagnostics & fault analysis and on error

messages.

Error number

Error text

Error type

Adjustable

in

hex

dec

(subject area

no.)

dec

(error no.)

0x01bc3100

444

12544

Connection to 8400 standard device lost

Error

-

0x01bc5531

444

21809

Memory: No access

Error

-

0x01bc5532

444

21810

Memory: Read error

Error

-

0x01bc5533

444

21811

Memory: Write error

Error

-

0x01bc6010

444

24592

Restart after watchdog reset

Error

-

0x01bc6011

444

24593

Internal error

Error

-

0x01bc6100

444

24832

Internal error

Error

-

0x01bc6101

444

24833

Internal error

Error

-

0x01bc6110

444

24848

Internal error

Error

-

0x01bc641f

444

25631

Invalid parameter set

Error

-

0x01bc6420

444

25632

Error: Lenze settings loaded

Error

-

0x01bc8130

444

33072

Profibus watchdog: Monitoring time elapsed

No response

C13880/1

0x01bc8131

444

33073

Profibus: Data_Exchange state exited

No response

C13880/1

0x01bc8132

444

33074

Profibus Watchdog: DP-V1 MSC2 monitoring time

exceeded

No response

C13880/2