Error messages
12.1
Short overview of the PROFIBUS error messages
91
Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12
Error messages
This chapter supplements the error list contained in the software manual and in the »Engineer«
online help for Inverter Drives 8400 by the error messages of the communication module.
12.1
Short overview of the PROFIBUS error messages
The following table lists all PROFIBUS error messages in numerical order of the error number.
Furthermore the preset error response and – if available – the parameters for setting the error
response are specified.
Tip!
When you click the cross-reference in the first column, you will see a detailed description
(causes and remedies) of this error message.
Software manual/online help for Inverter Drives 8400
Here you can find general information on diagnostics & fault analysis and on error
messages.
Error number
Error text
Error type
Adjustable
in
hex
dec
(subject area
no.)
dec
(error no.)
444
12544
Connection to 8400 standard device lost
Error
-
444
21809
Memory: No access
Error
-
444
21810
Memory: Read error
Error
-
444
21811
Memory: Write error
Error
-
444
24592
Restart after watchdog reset
Error
-
444
24593
Internal error
Error
-
444
24832
Internal error
Error
-
444
24833
Internal error
Error
-
444
24848
Internal error
Error
-
444
25631
Invalid parameter set
Error
-
444
25632
Error: Lenze settings loaded
Error
-
444
33072
Profibus watchdog: Monitoring time elapsed
No response
444
33073
Profibus: Data_Exchange state exited
No response
444
33074
Profibus Watchdog: DP-V1 MSC2 monitoring time
exceeded
No response