beautypg.com

5installation – Lenze E84AYCPM User Manual

Page 26

background image

Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17

26

5

Installation

5.2

Electrical installation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Activating the bus terminating resistor

( 27)

Number of stations

[5-6]

Number of stations

Tip!
Repeaters do not have a station address. When calculating the maximum number of

stations, they reduce the number of stations by 1 on each side of the segment.
Repeaters can be used to build up line and tree topologies. The maximum total bus system

expansion depends on ...

• the baud rate used;
• the number of repeaters used.

2133PFB004

M

1

2

3

S

S

S

S

S

R

R

Segment

Master (M)

Slave (S)

Repeater (R)

1

1

31

-

2

30

-

2

-

30

1

3

-

30

1