2 protective insulation, Protective insulation, 4technical data – Lenze E84AYCEO User Manual
Page 17
Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17
17
4
Technical data
4.2
Protective insulation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2
Protective insulation
Danger!
Dangerous voltage
If the Inverter Drives 8400 are operated on a phase-earthed mains with a rated mains
voltage of 400 V, external measures need to be implemented in order to ensure
protection against accidental contact.
Possible consequences:
Death or severe injuries
Protective measures:
If protection against accidental contact is required for the control terminals of the
inverter and the connections of the plugged device modules, ...
• a double isolating distance must exist.
• the components to be connected must be provided with the second isolating
distance.
Note!
The existing protective insulation in the Inverter Drives 8400 is implemented according
to EN 61800-5-1.