Kinze ISOBUS Electronics Package (3000 Series) Rev. 5/14 User Manual
Page 36

M0246
ISOBUS
30
Rev. 5/14
TM
SPEEd INPUT (Continued)
Planter Sensor Pulses per Mile
This box is for calibrating a planter mounted speed sensor. To calibrate:
1. Using a known speed value such as your tractor readout, start driving at your normal planting speed in a straight
line.
2. Compare the Planter Speed to the known speed source.
3. If the planter speed is too low or high compared to the known speed, stop driving to adjust the pulses per mile.
4. First divide the known speed by the planter speed.
5. Then divide the current pulses per mile by the number from step 4.
6. Enter this number in for the pulses per mile.
Example
Tractor Speed (known speed) – 5mph
Planter Speed – 3mph
Current Pulses per Mile – 50,500
5mph/3mph=1.67
50500/1.67=30,300
30,300 should be entered into the Pulses per Mile box
7. Repeat until Planter Speed is acceptable.
Manual Ground Speed
The manual ground speed can be used as a speed source if no other speed source is available. The speed that is
entered into the box is the speed that the planter will use for control and calculations. To use this speed as your source
select Manual from the Current Ground Speed Source list.
This value is also used for hydraulic drive jump start if it is installed. When the planter stops from a dead stop it takes
2-3 seconds to acquire ground speed from GPS or Radar therefore the manual speed is used for those first seconds
after start-up. Kinze recommends that the manual ground speed be set at 2mph.
Note: Manual Ground Speed selection is normally only used if the planter needs to be run while sitting still.
Speed Input values
The speed input list shows what each possible ground speed source is reading.
Settings